Developer Guide

Test Bench: Power & USB

Power and host connections

Single power inlet

External 12 V supply → inlet → main fuse → separately protected branches. Mains remains outside the box.

The external supply and XT60 connector set include the UK mains lead, panel inlet and matching cable connector. The supply's low-voltage car socket is replaced by the XT60H-M male cable plug, with insulated joints and strain relief. The capped XT60E-F female inlet mounts on the right side of the box; the mains lead remains unchanged. The supply is unplugged from mains before connecting or disconnecting the XT60, so the exposed cable contacts are unpowered.

Branch Connection
Pi Protected 12 V → Pi power board VIN solder pads → USB-C output → Pi.
Lighting Protected 12 V → 5 V converter → lighting fuse → LED strip and data buffer.
Logic 5 V converter → separate logic fuse → LCD, I²C high side and sensor power.
Yellow output lamps Protected 12 V → two independent MOSFET lamp circuits.
Blue button rings Protected 12 V → steady backlight bus.

All low-voltage circuits share a common ground. LED load current returns directly to the converter, not through the ESP or USB. The Pi supply, fused lighting/logic feeds and USB VBUS remain separate: converter outputs are not paralleled and branch fuses are not bridged. Each five-way WAGO joins all five ports into one node.

The four-way fuse block uses three positions for the Pi converter, lighting/logic converter and 12 V indicators; one is spare. Three inline holders provide the main 12 V, 5 V lighting and 5 V logic fuses. Fuse ratings and wire sizes must match the loads, cables and connectors.

Pi power board

The Pi power board is listed as P24 in the shopping list.

The Pi bay includes clearance for the cooler and cable bends.

Power budget

Load Planning allowance
Pi and USB peripherals 25.5 W
Up to 102 addressable pixels 30.6 W / 6.12 A at 5 V
Sensors, LCD and interfaces 5 W
12 V lamps and button rings 10 W

At 80–90% converter efficiency, the estimated demand is 6.5–7.2 A at 12 V. The supply specification is an enclosed 12 V / 10 A unit. These are design allowances rather than measured consumption; real coils are outside this budget.

USB connection

A data-capable cable connects the control host to the ESP's serial/programming USB-C port. USB also powers the ESP. There is one host connection and no parallel feed into the ESP's USB-powered 5 V rail.

In Development

Find your next step.

Type to search the site.

Fit