Bridge Protocol

The Pi owns the ESP's USB serial connection through the bridge daemon. Each frame starts with a four-byte unsigned big-endian length. That length counts all bytes after the header, including the type byte when present. The firmware assembles partial reads and accepts payload lengths from 1 to 8,192 bytes.

During handshake, the bridge negotiates protocol v2. Untyped command frames carry UTF-8 JSON directly. A typed frame starts its payload with type 1 for JSON, type 2 for binary blob data, type 3 for diagnostic text or type 4 for a compact ESP event. Commands use JSON objects with a cmd field. Update firmware and the Pi bridge together for compact events.

Commands and replies

Command or response Use
HELLO, GET_INFO Negotiate protocol and discover controller identity and rules runtime support.
EVENT_FIRE, EVT, EVENT_DROP Send a synthetic event and observe its acknowledgement or drop.
BLOB_BEGIN, binary chunks, BLOB_END Transfer compiled mapping, rules or lighting data. Check the apply result and manifest.
COIL_CONFIG, COIL_HEARTBEAT, COIL_STATUS Configure limits, prove bridge liveness and read the ESP's safety state.
GET_INPUT_LEVELS, INPUT_LEVELS Read up to 16 watched input sources.
GET_RUNTIME_CLOCK, RULE_ACTIONS Obtain current ESP time and submit time-limited Pi-side output decisions.

Use bridge RPC and reqId for a correlated command response. Unsolicited status and event frames carry a message type in t. A heartbeat status updates the safety display. An explicit coil command needs its own correlated reply.

Deployment

Hardware Sync first sends the coil limits, then applies the compiled mapping. Rules Sync sends rules.pd, which includes input watches needed by managers. Lighting uses its own compiled blob. A success requires firmware apply confirmation and an updated manifest entry. Bridge performance

Event provenance and safety

Physical input frames carry provenance, sequence, time, event name and type, rules version, and the electrical level and gesture duration when available. The bridge expands them to the usual EVT record with physical:true and full device observations for rules and logging. EVENT_FIRE confirmations use synthetic:true. Missing watched-input values leave occupancy unconfirmed.

Compact event frames

The type 4 payload starts with flags, the rules version, a 32-bit sequence and a 32-bit ESP millisecond timestamp. An optional 32-bit gesture duration follows. All multibyte integers are big-endian. The source and event type are UTF-8 strings prefixed with a 16-bit byte length. The name is either another length-prefixed string or reconstructed from the type, source, or source and type joined by an underscore.

The flags use bits 0–1 for input level (0 unknown, 1 low, 2 high), bits 2–3 for the name form (0 literal, 1 type, 2 source plus type, 3 source), bit 4 for duration, and bit 5 for physical input. Bits 6–7 are reserved. Each device observation has a one-byte prefix length shared with the source, a one-byte state code and a length-prefixed suffix. State codes 1–6 correspond to Closed, Open, High, Low, Active and Inactive. Observations continue to the end of the frame. Every frame carries its own complete snapshot.

Diagnostic stream frames use the same type with physical provenance absent, an empty event type and rules version 0. The ESP retains physical events in order when the transmit queue is temporarily full. If the input buffer overflows, the ESP reports the number discarded in EVENT_INPUT_LOSS and the Bridge enters overload recovery. Expanded physical events appear in both the ESP raw log and the event audit log.

An ESP event reports which rules runtime version was active for that event. Version 3 applies supported local actions from mixed rules. Pi-side output decisions still go through RULE_ACTIONS, which validates timing and input state before sending an action through the coil policy. Coil Safety

Hardware Test

HARDWARE_TEST uses a browser-generated session ID and replies with HARDWARE_TEST_STATUS and the correlated request ID. start lists the applied driver's test actions and current state for each mapped device. poll renews the session and returns device status in the same order. It can also renew a lamp hold by device ID. action executes a supported driver test by device ID, and stop returns test outputs to idle. The ESP takes care of output cleanup when the session or a hold expires. This traffic uses bridge RPC and does not generate gameplay events.