Direct sensor connections

Eight break-beam pairs connect to eight ESP inputs. The sensors are listed as P05 in the shopping list.

Connection Wiring
Emitter Red → protected 5 V logic supply; black → common ground.
Receiver power Red → the same 5 V logic supply; black → common ground.
Receiver signal White → ESP input with a 3.3 V pull-up; requires verified 0–3.3 V compatibility.

Wire identification and signal voltage are checked with the ESP disconnected. The signal must stay within 0–3.3 V, including startup. An output that drives or pulls up to 5 V requires a level interface; ESP inputs must not be pulled up to 5 V.

Separate transitions between touching balls determine the beam alignment and debounce setting. Sensor power comes from the supply rail, not a GPIO.

Flipper inputs and coil-output lamps

Each flipper has a blue input button and a separate yellow output lamp.

Path Connection
Button Normally-open contacts → ESP input and ground through the interface board.
Yellow lamp ESP output → MOSFET control input; protected 12 V → the module's labelled lamp-load terminals.
Blue button ring Separate, steady 12 V backlight supply, electrically separate from the switch contacts.

Each yellow lamp has its own MOSFET. The control circuit requires the correct input polarity and an OFF state during boot/reset. ESP arming, watchdog and pulse limits remain active. The lamps show output activity; they do not reproduce real coil current, flyback or pulse timing.

LED strip and signal interfaces

Strip section Pixels Nominal length
Continuous perimeter 89 1.483 m
Console status row 6 100 mm
Console key-light row 6 100 mm
Total 101 1.683 m

The 2 m roll leaves 19 spare pixels. The power budget allows 102 pixels for final fitting.

The perimeter strip runs inside the walls at z≈110, with its feed gap on the right near y=285. Pixels and factory joins sit clear of bends. Retained leads run down the right wall through the console passage. Power enters at the start and roughly opposite side; data chains from the perimeter to the two console rows.

Interface Connection
74AHCT125 buffer ESP 3.3 V LED data → 5 V strip data, through 330 Ω. One channel serves the chained strip.
Bidirectional I²C level shifter ESP SDA/SCL at 3.3 V ↔ LCD SDA/SCL at 5 V.

The interface-board drawings show component pinouts, unused-input connections and decoupling. LCD configuration must match the display's I²C address and driver.

Panel status indicators

The ten fixed-colour P25 indicators use one P26 controller, with six channels spare. The circuit uses 5 V lamps, 3.3 V I²C logic and open-drain outputs.

Lamp current must remain within the controller's output ratings; resistors or a separate driver stage are required where it exceeds those ratings. I²C pull-ups stay at 3.3 V, with a common ground.