Coil operating modes
Under Hardware, set Function → Coil, Driver → Default, then open that pin's driver options. PIN Safe remains the electrical OFF level. Rule ON/OFF is logical activation/release for coils, regardless of that electrical level.
New coils default to Disabled under Coil operation, Pulse only, a 10 ms normal pulse, a 20 ms hard pulse limit, and 1,000 ms cooldown. Choose limits for the actual coil and power driver. Save Changes persists the mapping on the Pi, and Sync to ESP deploys the settings. Automatic arming, heartbeat recovery and the Dashboard status are covered in Coil Safety.
| Mode | Rule ON | Rule OFF |
|---|---|---|
| Pulse only | Run the configured pulse, then turn off automatically | Stop immediately |
| Pulse + PWM hold | Initial pulse, then configured PWM duty | Stop both pulse and hold |
| Separate power and hold | Pulse the power winding, turn it off, then energize the linked hold winding | Turn both windings off |
| Continuous duty | Activate an explicitly continuous-rated output | Turn off |
| Hold winding | Independent activation is rejected; controlled by the paired power pin | Release the whole pair |
A PULSE rule always performs a finite pulse without entering hold, including on a hold-capable primary output. Its duration must not exceed the hard pulse limit. Repeated ON/PULSE commands do not extend an existing activation. An activation during cooldown is ignored immediately. The next eligible press can fire normally, and other coils remain available. A hold or continuous timeout latches a fault and shuts all coils down; it never becomes an unlimited hold. Hold time is measured after the initial pulse; continuous time is measured from activation. Limits range from 1–1,000 ms for a pulse and 1–60,000 ms for hold/continuous activation. Cooldown is 1–60,000 ms and must be at least the hard pulse limit.
For a paired coil, configure one pin as Hold winding, then select it in the power pin's Separate power and hold options. Configure both rows before saving. Each retains its own PIN Safe and cooldown; the assembly's hold limit cannot exceed the secondary winding's limit. Both must be enabled before the primary can be enabled. Only the primary appears as an output in the rules editor. Sharing a hold winding between assemblies is rejected.
PWM has no assumed safe duty: its default is 0%, and enabling PWM hold requires choosing 5–95% in 5% steps. Default firmware supports 50, 100, 250 and 500 Hz using a 100 µs interrupt tick. This is switching duty, not measured current or power. A board with internal pulse/hold control requires a dedicated driver; Default does not claim board-managed hold or higher-frequency PWM support.
The firmware enforces arming, pin ownership, deadlines, cooldown and host/loop watchdogs independently of rule timers. Removing a reserved coil pin or changing its PIN Safe during a live boot is rejected. Native policy tests and ESP32-S3 compilation do not qualify the electrical hardware: actual PWM timing, current, thermal behaviour and shutdown under load still need hardware validation.